		<item>
		<title>Купуване на дозиметър или радиометър?</title>
		<link>http://metroion.com/buying-dosimeter_and_radiometer/</link>
		<comments>http://metroion.com/buying-dosimeter_and_radiometer/#comments</comments>
		<pubDate>Mon, 22 Oct 2012 10:20:30 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Йонизиращи лъчения]]></category>
		<category><![CDATA[величина]]></category>
		<category><![CDATA[грешка]]></category>
		<category><![CDATA[дозиметър]]></category>
		<category><![CDATA[енергиен обхват]]></category>
		<category><![CDATA[обхват]]></category>
		<category><![CDATA[радиометър]]></category>

		<guid isPermaLink="false">http://metroion.com/?p=1441</guid>
		<description><![CDATA[Преди да си купите дозиметър или радиометър в областта на йонизиращите лъчения, трябва да сте наясно за какво ще го използвате. След като знаете къде и за какво ще го използвате е необходимо да прецените какъв обхват на измерване ви е необходим, каква величина ще измервате (обикновено еквивалентна доза за дозиметър и скорост на излъчване<a href="http://metroion.com/buying-dosimeter_and_radiometer/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;">Преди да си купите дозиметър или радиометър в областта на йонизиращите лъчения, трябва да сте наясно за какво ще го използвате. След като знаете къде и за какво ще го използвате е необходимо да прецените какъв обхват на измерване ви е необходим, каква величина ще измервате (обикновено еквивалентна доза за дозиметър и скорост на излъчване на частици за радиометър), каква грешка на измерване има уреда и т.н. Днес повечето дозиметри и радиометри измерват в доста широки граници, като това което търсите ще определите вие според нуждите ви. Ако се затруднявате, по-добре е да използвате посредник, като това ще ви спести много главоболия (вижте страница &#8220;<a title="Фирми" href="http://metroion.com/organizations/companies_in_metrology/" target="_blank">Фирми</a>&#8220;).<span id="more-1441"></span></span></p>
<p><span style="color: #000000;">Ще структурирам стъпките  при закупуването на уреда:</span></p>
<p align="justify"><strong><span style="color: #000000;">1. Преценете добре за какво ще използвате уреда, за да не се окаже, че сте дали няколко хиляди лева за неизползваемо средство за измерване.</span></strong><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;">Едни от най-важните характеристики са:</span></p>
<p><span style="color: #000000;">  &#8211;   величина на измерване (обикновено поддържат няколко);</span></p>
<p><span style="color: #000000;">  &#8211;   обхват на измерване;</span></p>
<p><span style="color: #000000;">  &#8211;   енергиен обхват на измерване;</span></p>
<p><span style="color: #000000;">  &#8211;   грешка на измерване.</span><span style="color: #000000;"> </span></p>
<p align="justify"><span style="color: #000000;"><span style="text-decoration: underline;">Важно</span>: Ако си закупите комбиниран уред за измерване, ще икономисате пари, т.е. това са уреди работещи едновременно като дозиметри и радиометри, с помощта на подходящ набор от детектори.</span></p>
<p><strong><span style="color: #000000;">2. Проверете уреда, който желаете дали е от одобрен тип.</span></strong></p>
<p align="justify"><span style="color: #000000;">Това можете да го направите в сайта на <a title="Българския Институт по Мтерология" href="http://www.bim.government.bg/" target="_blank">Българския Институт по Мтерология</a>, тъй като той е отговорен за одобряването на типовете уреди за измерване. Отидете към Регистъра <a title="РЕГИСТЪР" href="http://www.bim.government.bg/BIM/bim.nsf/index.xsp?page=ABF79904533B9B59C225789400225C63" target="_blank">»»»»»</a> </span></p>
<p align="justify"><span style="color: #000000;"><span style="text-decoration: underline;">Важно</span>: Ако уреда не е от одобрен тип, по-добре не го купувайте, защото той ще е със статут „незаконен” и не подлежи на ежегодна проверка, като няма да можете да го използвате за измервания, които трябва да удостоверявате. Това означава, че ако имате работа с <a title="Агенция за Ядрено Регулиране" href="http://www.bnsa.bas.bg/" target="_blank">Агенцията за Ядрено Регулиране</a>, те няма да ви признаят резултатите от вашето измерване. По-друг начин седи въпроса с калибрирането. Там не е нужно уреда да е от одобрен тип. Калибрирането в България се извършва от Българския Институт по Мтерология в град Ловеч и се признава от <a title="Българска Служба по Акредитация" href="http://nab-bas.bg/bg" target="_blank">Българската Служба по Акредитация</a>.</span></p>
<p><strong><span style="color: #000000;">3. Бюджет.</span></strong></p>
<p align="justify"><span style="color: #000000;">След като сте наясно с положенията описани по-горе и знаете с какъв бюджет разполагате, трябва да проучите какви уреди има на пазара, които покриват вашите изисквания, посочени в точка 1. Може да използвате страницата „</span><a style="color: #ff4500;" title="Фирми" href="http://metroion.com/organizations/companies_in_metrology/" target="_blank">Фирми</a><span style="color: #000000;">” и да отправите запитване към тях, които от своя страна трябва да ви изготвят оферта. Така ще прецените кое е най-изгодно за вас.</span></p>
<p align="justify"><span style="color: #000000;">Ако разполагате със скромен бюджет трябва да си купите уред от някоя страна от бившата СССР, но не ви го препоръчвам. Опита, които имам с различни видове уреди ми е показал, че уредите произведени в Западна Европа, потвърждават много по-добре характеристиките си, посочени от производителя.</span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"><strong><span style="text-decoration: underline;">Препоръчани дозиметри, радиометри или комбинирани</span></strong><strong><span style="text-decoration: underline;"> уреди</span></strong><strong>:</strong></span></p>
<p style="text-align: left;"><span style="text-align: center;">                                                                                          </span><span style="text-align: center;">                          </span></p>
<p><span style="color: #000000;"><img class="alignleft size-full wp-image-1446" title="FH 40 G" src="http://metroion.com/wp-content/uploads/2012/10/FH-40-G.jpg" alt="FH 40 G " width="130" height="256" /><span style="text-align: center;">FH 40 G                               </span></span></p>
<p style="padding-left: 120px;"><span style="color: #000000;"><span style="text-align: center;">                   InSpector™ 1000  </span><span style="text-align: center;"> </span><img class="size-full wp-image-1447" style="border: 1px solid black;" title="InSpector™ 1000" src="http://metroion.com/wp-content/uploads/2012/10/InSpector™-1000.jpg" alt="" width="160" height="221" /></span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span><span style="color: #000000;"><span style="text-align: center;">       </span></span><span style="text-align: center; color: #000000;"> </span><span style="text-align: center;"> </span><span style="color: #000000; text-align: center;">         </span><span style="color: #000000;"> </span><span style="color: #000000; text-align: center;">                               </span></p>
<p><span style="color: #000000;"><span style="color: #000000;"><img class="size-full wp-image-1450 alignleft" style="border: 1px solid black;" title="Radiagem 2000" src="http://metroion.com/wp-content/uploads/2012/10/Radiagem-2000.jpg" alt="" width="171" height="189" /></span><span style="text-align: center;">Radiagem™-2000/4000</span>             </span></p>
<p><span style="color: #000000;">              </span><span style="color: #000000; text-align: center;">Berthold LB 123 D</span><span style="color: #000000;"> </span><img class="size-full wp-image-1449" style="border: 1px solid black;" title="Berthold LB 123 D" src="http://metroion.com/wp-content/uploads/2012/10/Berthold-LB-123-D.jpg" alt="" width="134" height="201" /></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span><span style="color: #000000; text-align: center;">                                       </span></p>
<p><span style="color: #000000; text-align: center;">              </span><span style="color: #000000;"> </span><span style="color: #000000;">   </span><span style="color: #000000; text-align: center;">                             </span></p>
<p><span style="color: #000000;"><span style="color: #000000;"><img class="alignleft size-full wp-image-1451" style="border: 1px solid black;" title="RDS-110" src="http://metroion.com/wp-content/uploads/2012/10/RDS-110.jpg" alt="" width="145" height="145" /></span></span><span style="color: #000000; text-align: center;">RDS-110</span><span style="color: #000000;">                   </span></p>
<p><span style="color: #000000;">           Automess 6150AD</span><span style="color: #000000;">  </span><img class="size-full wp-image-1448" style="line-height: 19px; border: 1px solid black;" title="Automess 6150AD" src="http://metroion.com/wp-content/uploads/2012/10/Automess-6150AD.jpg" alt="" width="199" height="192" /></p>
<p><span style="text-align: center; color: #000000;">  </span></p>
<h5><span style="color: #000000;"><strong><em>Автор: Росен Иванов  </em>  </strong></span></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/buying-dosimeter_and_radiometer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Методи за измерване в дозиметрията</title>
		<link>http://metroion.com/method-measuring-in-dosimetry/</link>
		<comments>http://metroion.com/method-measuring-in-dosimetry/#comments</comments>
		<pubDate>Fri, 28 Sep 2012 11:33:48 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Област Дозиметрия]]></category>
		<category><![CDATA[дозиметрия]]></category>
		<category><![CDATA[дозиметър]]></category>
		<category><![CDATA[измерване]]></category>
		<category><![CDATA[калибриране]]></category>
		<category><![CDATA[методи]]></category>
		<category><![CDATA[сравнение]]></category>

		<guid isPermaLink="false">http://localhost/MetroIon/?p=1162</guid>
		<description><![CDATA[Калибрирането се извършва по метода на: сравнение; заместване; преки измервания; едновременното измерване; абсолютното измерване. Въведение Като цяло, референтните инструменти не измерват пряко подходящите еквивалентни величини за калибриране или изпитване. Вместо това, най-често референтните инструменти се използват за характеризиране на радиационни полета чрез други измервателни величини като въздушна керма за фотонно лъчение. Величината еквивалентна доза се получава от основни<a href="http://metroion.com/method-measuring-in-dosimetry/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p><span style="color: #000000;"><strong>Калибрирането се извършва по метода на:</strong></span></p>
<ul>
<li><span style="color: #000000;">сравнение;</span></li>
<li><span style="color: #000000;">заместване;</span></li>
<li><span style="color: #000000;">преки измервания;</span></li>
<li><span style="color: #000000;">едновременното измерване;</span></li>
<li><span style="color: #000000;">абсолютното измерване.</span></li>
</ul>
<p><span style="color: #000000;"><strong>Въведение</strong></span></p>
<p align="justify"><span style="color: #000000;">Като цяло, референтните инструменти не измерват пряко подходящите еквивалентни величини за калибриране или изпитване. Вместо това, най-често референтните инструменти се използват за характеризиране на радиационни полета чрез други измервателни величини като въздушна керма за фотонно лъчение. Величината еквивалентна доза се получава от основни радиационни величини с подходящи коефициенти за преобразуване.<span id="more-1162"></span></span></p>
<p align="justify"><span style="color: #000000;">Трябва да се направи разграничение между четири метода на калибриране, които могат да бъдат използвани. Ако се използва референтен инструмент (обозначен с долно R по-надолу), калибрационния фактор, N<sub>R</sub>, даден в сертификата за калибриране, може да се използва, за да се определи истинската стойност на еквивалентната доза H с помощта на конверсионния коефициент h за еквивалентната доза H и измерената M<sub>R </sub>стойност на референтния инструмент (коригирани за референтни условия):</span></p>
<p style="text-align: center;" align="justify"><span style="color: #000000;"><img class="aligncenter  wp-image-1168" title="Dose" src="http://metroion.com/wp-content/uploads/2012/09/Dose2.jpg" alt="" /></span></p>
<p style="text-align: left;"><span style="color: #000000;">(а) където референтния инструмент отчита една и съща измервана величина, както инструмента, подлежащ на калибриране:</span></p>
<p style="text-align: center;"><span style="color: #000000;"> h = 1</span></p>
<p align="justify"><span style="color: #000000;">(б) когато референтния инструмент показва величина, различна от тази на инструмента, подлежащ на калибриране. Тук трябва да се прилага подходящ конверсионнен коефициент h.</span></p>
<p style="text-align: center;"><span style="color: #000000;"> </span></p>
<h5 style="text-align: center;"><span style="color: #000000;"><span style="color: #000000;"><img class="aligncenter  wp-image-1174" style="border: black 1px solid;" title="Calibration methods" src="http://metroion.com/wp-content/uploads/2012/09/Calibration-methods.jpg" alt="" width="537" height="744" /></span><em>Четири метода за калибриране.  Метод 1:  Калибриране с референтен инструмент без монитор; Метод 2: Калибриране с референтен инструмент с монитор; Метод 3: Калибриране чрез заместване; Метод 4: Калибриране в познато радиационно поле.</em></span></h5>
<p style="text-align: left;"><span style="color: #000000;">  </span></p>
<p align="justify"><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Измервания без монитор на изхода на източника (Метод на калибриране 1)</strong></span></span></p>
<p align="justify"><span style="color: #000000;">Тази процедура е подходяща, ако стойността на физична величина, характеризираща радиационното поле (напр. мощност на въздушната керма) е стабилна в продължение на период от време, съответстваща на продължителността на калибрирането, до степента, до която са постигнати резултатите от желаната точност. Калибрирането се извършва при стандартни тестови условия, близки до референтните условия. Референтните точки на референтния инструмент и инструмента, подлежащ на калибриране впоследствие се позиционират на мястото на теста на радиационното поле за калибриране по отношение на величината еквивалентна доза H.</span></p>
<p align="justify"><span style="color: #000000;">За референтните инструмент (долен R), се получава (1):</span></p>
<p style="text-align: center;"><span style="color: #000000;"><img class="size-full wp-image-1186 aligncenter" title="1" src="http://metroion.com/wp-content/uploads/2012/09/1.jpg" alt="" width="86" height="42" /></span><span style="color: #000000;">и за инструмента подлежащ на калибриране (долен I), чиято индикация е пряко свързана с величината еквивалентна доза H, получаваме (2):</span></p>
<p style="text-align: center;"> <img class="aligncenter size-full wp-image-1187" title="2" src="http://metroion.com/wp-content/uploads/2012/09/2.jpg" alt="" width="67" height="42" /></p>
<p align="center"><span style="color: #000000;">                                 </span></p>
<p align="justify"><span style="color: #000000;">Комбинацията от двете формули (1) и (2) по-горе ни дават калибрационния фактор N<sub>I</sub>:</span></p>
<p style="text-align: center;"> <img class="aligncenter size-full wp-image-1192" title="1-2" src="http://metroion.com/wp-content/uploads/2012/09/1-2.jpg" alt="" width="105" height="42" /></p>
<p><span style="color: #000000;">където:</span></p>
<p><span style="color: #000000;">N<sub>R</sub> е калибрационния фактор на референтния инструмент (при референтни условия);</span></p>
<p><span style="color: #000000;">N<sub>I </sub>е калибрационния фактор на инструмента подлежащ на калибриране (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">M<sub>R</sub> е измерената стойност от референтния инструмент, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p align="justify"><span style="color: #000000;">М<sub>I</sub> е измерената стойност от инструмента подлежащ на калибриране, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p><span style="color: #000000;">h е конверсионния коефициент.</span></p>
<p>&nbsp;</p>
<p><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Измервания с монитор на изхода на източника (Метод на калибриране 2)</strong></span></span></p>
<p align="justify"><span style="color: #000000;">Умерените вариации във физическите величини, които характеризират дозиметричените свойства на радиационно поле (например мощност на въздушната керма) с течение на времето могат да бъдат коригирани последователно с помощта на монитор и от облъчването на референтния инструмент и инструмента, подлежащ на калибриране. Тази техника често се използва в рентгеновата област с цел да се коригира вариацията на мощността на въздушната керма, когато последователно референтния инструмент и инструмента, подлежащ на калибриране се поставят на мястото на измерване.</span></p>
<p align="justify"><span style="color: #000000;">Величината еквивалентна доза H в точката на измерване е свързана с калибрационния </span><span style="color: #000000;">фактор на камерата на монитора, N<sub>M</sub>, и измерените стойности m чрез <span style="color: #000000;">(3)</span></span></p>
<p style="text-align: center;" align="justify"><span style="color: #000000;"> </span> <img class="aligncenter size-full wp-image-1188" title="3" src="http://metroion.com/wp-content/uploads/2012/09/3.jpg" alt="" width="65" height="35" /></p>
<p style="text-align: center;" align="justify"><span style="color: #000000;">Съответните уравнения за референтния инструмент и инструмента, подлежащ на калибриране са  (4) <span style="color: #000000;">и (5)</span>:</span> <span style="color: #000000;">   <img class="aligncenter size-full wp-image-1189" title="4" src="http://metroion.com/wp-content/uploads/2012/09/4.jpg" alt="" width="80" height="42" /><img class="aligncenter size-full wp-image-1190" title="5" src="http://metroion.com/wp-content/uploads/2012/09/5.jpg" alt="" width="64" height="40" /></span></p>
<p style="text-align: left;"><span style="color: #000000;">Величината H може да бъде елиминирана в уравнения (4) и (5) с помощта на уравнение (3), като получаваме (6) и (7):</span></p>
<p style="text-align: center;"> <img class="aligncenter size-full wp-image-1191" title="6" src="http://metroion.com/wp-content/uploads/2012/09/6.jpg" alt="" width="100" height="42" /></p>
<p style="text-align: center;" align="center"><span style="color: #000000;">         <img class="aligncenter size-full wp-image-1193" title="7" src="http://metroion.com/wp-content/uploads/2012/09/7.jpg" alt="" width="92" height="42" />           </span></p>
<p style="text-align: left;"><span style="color: #000000;">Разделяйки уравнение (7) на уравнение (6) се довежда до премахване на калибрационния фактор N<sub>M</sub> и получаваме за N<sub>I</sub>:   </span><span style="color: #000000;"> </span></p>
<p style="text-align: center;"> <img class="aligncenter size-full wp-image-1194" title="6-7" src="http://metroion.com/wp-content/uploads/2012/09/6-7.jpg" alt="" width="159" height="42" /></p>
<p><span style="color: #000000;">където</span></p>
<p style="text-align: left;"><span style="color: #000000;">N<sub>R</sub> е калибрационния фактор на референтния инструмент (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">N<sub>I </sub>е калибрационния фактор на инструмента подлежащ на калибриране (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">M<sub>R</sub> е измерената стойност от референтния инструмент, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p align="justify"><span style="color: #000000;">М<sub>I</sub> е измерената стойност от инструмента подлежащ на калибриране, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p align="justify"><span style="color: #000000;">m<sub>R</sub> е измерената стойност на монитора за облъчването на референтния инструмент, коригирана за референтни условия;</span></p>
<p align="justify"><span style="color: #000000;">m<sub>I</sub> е измерената стойност на монитора за облъчването на инструмента, подлежащ на калибриране, коригирана за референтни условия;</span></p>
<p><span style="color: #000000;">h е конверсионния коефициент.</span></p>
<p>&nbsp;</p>
<p align="justify"><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Калибриране чрез едновременно облъчване на двата дозиметъра (Метод на калибриране 3)</strong></span></span></p>
<p align="justify"><span style="color: #000000;">В някои случаи калибрирането може да се извършва чрез едновременно облъчване на детекторите на референтния инструмент и инструмент подлежащ на калибриране, като се поставят симетрично на оста на радиационно поле, на едно и също разстояние от източника. Разстоянието между двата детектора трябва да бъде достатъчно голямо, за да не  бъде повлияна от присъствието на другия инструмент.</span></p>
<p align="justify"><span style="color: #000000;">На първо място, тази процедура ще се прилага за тези случаи, когато не е необходимо да има фантом. Тази техника се използва особено за референтни радиационни процедури от ускорители или при използване на неколимирани източници.</span></p>
<p align="justify"><span style="color: #000000;">Мощността на еквивалентната доза H при две симетрични точки на калибриране е свързана с калибрационния фактор на референтния инструмент в точката на калибриране №1,<em> (8)</em>:</span></p>
<p style="text-align: center;" align="justify"> <img class="aligncenter size-full wp-image-1197" title="8" src="http://metroion.com/wp-content/uploads/2012/09/8.jpg" alt="" width="103" height="44" /><span style="color: #000000;">както и в точка на калибриране № 2 на инструмента подлежащ на калибриране (9),</span></p>
<p style="text-align: center;">  <img class="aligncenter size-full wp-image-1198" title="9" src="http://metroion.com/wp-content/uploads/2012/09/9.jpg" alt="" width="87" height="44" /></p>
<p align="center"><span style="color: #000000;">              </span></p>
<p style="text-align: left;"><span style="color: #000000;">За да се премахне влиянието на асиметрия на радиационното поле, измерванията се повтарят след размяна на позициите на двата инструмента, ние получаваме (10) и  (11)</span></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-1199" title="10" src="http://metroion.com/wp-content/uploads/2012/09/10.jpg" alt="" width="103" height="44" /></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-1200" title="11" src="http://metroion.com/wp-content/uploads/2012/09/11.jpg" alt="" width="87" height="44" /></p>
<p align="justify"><span style="color: #000000;">H<sub>1</sub> и H<sub>2</sub> могат да бъдат елиминирани чрез комбиниране на уравненията (8) и (11), и уравненията (9) и (10), съответно (12) и (13):</span></p>
<p style="text-align: center;"> <span style="color: #000000;">                 <img class="aligncenter size-full wp-image-1202" title="12" src="http://metroion.com/wp-content/uploads/2012/09/12.jpg" alt="" width="103" height="44" />      <img class="aligncenter size-full wp-image-1203" title="13" src="http://metroion.com/wp-content/uploads/2012/09/13.jpg" alt="" width="103" height="44" /></span></p>
<p style="text-align: left;"><span style="color: #000000;">Умножаването на уравненията (12) и (13) води до</span></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-1204" title="12-13" src="http://metroion.com/wp-content/uploads/2012/09/12-13.jpg" alt="" width="202" height="62" /></p>
<p><span style="color: #000000;">където</span></p>
<p style="text-align: left;"><span style="color: #000000;">N<sub>R</sub> е калибрационния фактор на референтния инструмент (при референтни условия);</span></p>
<p><span style="color: #000000;">N<sub>I </sub>е калибрационния фактор на инструмента подлежащ на калибриране (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">(M<sub>R</sub>/M<sub>I</sub>)<sub>1 </sub>е измерената стойност на референтния инструмент, разделена на съответната стойност на инструмента, подлежащ на калибриране в точка за калибриране № 1, коригирани за референтни условия;</span></p>
<p align="justify"><span style="color: #000000;">(M<sub>R</sub>/M<sub>I</sub>)<sub>2 </sub>е измерената стойност на референтния инструмент, разделена на съответната стойност на инструмента, подлежащ на калибриране в точка за калибриране № 2, коригирани за референтни условия;</span></p>
<p style="text-align: left;"><span style="color: #000000;">h е конверсионния коефициент.</span></p>
<p style="text-align: left;"><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Калибриране в познато радиационно поле (Метод на калибриране 4)</strong></span></span></p>
<p align="justify"><span style="color: #000000;">За радиационното поле, за което е известно стойността на еквивалентната доза H в точката на калибриране, калибрирационния фактор на инструмента N<sub>I</sub>, се получава чрез</span></p>
<p style="text-align: center; padding-left: 60px;" align="center"><span style="color: #000000;">N<sub>I</sub> = H / M<sub>I</sub>                     (14)</span></p>
<p style="text-align: left;"><span style="color: #000000;">където</span></p>
<p align="justify"><span style="color: #000000;">N<sub>I </sub>е калибрационния фактор на инструмента подлежащ на калибриране (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">М<sub>I</sub> е измерената стойност от инструмента, подлежащ на калибриране, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p align="justify"><span style="color: #000000;">H е истинската стойност на еквивалентната доза, която се измерва.</span></p>
<p>&nbsp;</p>
<h5><span style="color: #000000;"><em><strong>Автор: Росен Иванов</strong></em></span></h5>