<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Мetroion &#187; MetroIon</title>
	<atom:link href="http://metroion.com/author/admin/feed/" rel="self" type="application/rss+xml" />
	<link>http://metroion.com</link>
	<description></description>
	<lastBuildDate>Wed, 30 Jan 2013 13:25:00 +0000</lastBuildDate>
	<language>bg-BG</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	
		<item>
		<title>Повърхностни радиоактивни замърсявания</title>
		<link>http://metroion.com/surface_radioactive_contamination/</link>
		<comments>http://metroion.com/surface_radioactive_contamination/#comments</comments>
		<pubDate>Thu, 08 Nov 2012 09:37:27 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Категории]]></category>
		<category><![CDATA[Област Активност]]></category>
		<category><![CDATA[активност]]></category>
		<category><![CDATA[видове замърсяване]]></category>
		<category><![CDATA[замърсяване]]></category>
		<category><![CDATA[радиоактивен замърсител]]></category>
		<category><![CDATA[радиоактивно замърсяване]]></category>
		<category><![CDATA[радиоактивност]]></category>

		<guid isPermaLink="false">http://metroion.com/?p=1510</guid>
		<description><![CDATA[Радиоактивното  замърсяване на повърхности може да е резултат от ядрени инцидент, също от разливане, изпръскване или изтичане от открити източници. То може да породи опасност за здравето. Ето защо, повърхностно замърсяване трябва да бъде следено и контролирано. Измерването на количеството радиоактивно вещество отложено върху повърхност се постига на първо място чрез използването на радиометри (монитори)<a href="http://metroion.com/surface_radioactive_contamination/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;">Радиоактивното  замърсяване на повърхности може да е резултат от ядрени инцидент, също от разливане, изпръскване или изтичане от открити източници. То може да породи опасност за здравето. Ето защо, повърхностно замърсяване трябва да бъде следено и контролирано.</span></p>
<p align="justify"><span style="color: #000000;">Измерването на количеството радиоактивно вещество отложено върху повърхност се постига на първо място чрез използването на радиометри (монитори) за повърхностно замърсяване. За да бъдат направени точни оценки на повърхностното замърсяване е необходимо тези радиометри да бъдат калибрирани с еталонни източници, които са проследими към национални еталони. Тези еталонни източници могат да се характеризират чрез величината <em>активност</em> или величината <em>скорост на излъчване на частици</em><em> </em><em>от повърхност</em> или и чрез двете.   </span></p>
<p align="justify"><span style="color: #000000;">Както националните така и международните организации дават насоки за препоръчаните еталонни източници на различни нива на точност и проследимост.</span></p>
<p align="justify"><span style="color: #000000;">Съгласно Наредбата за основните норми за радиационна защита, 2004, границите на повърхностното радиоактивно замърсяване са дефинирани в единицата <em>частици.cm<sup>-2</sup>.min<sup>-1</sup></em>, което налага повърхностното радиоактивно замърсяване на национално ниво да се характеризира с величината  <em>скорост на излъчване на частици</em><em> </em><em>от повърхност.<span id="more-1510"></span></em></span></p>
<h3 align="justify"><strong><span style="color: #000000;"><span style="text-decoration: underline;">Целите на измерване на повърхностно замърсяване са</span>:</span></strong></h3>
<ul>
<li><span style="color: #000000;">първо, да се регистрира замърсяването, така че да се определи неговото </span><span style="color: #000000;">съществуване и да се контролира разпространението му;</span></li>
</ul>
<ul>
<li><span style="color: #000000;">второ, да се определи скоростта на излъчване на частици (активността) на единица площ, за да се провери, дали не са превишени допустимите граници.</span></li>
</ul>
<p align="justify"><strong><span style="color: #000000;">При определяне на повърхностни радиоактивни замърсявания се вземат предвид няколко фактора:</span></strong></p>
<p align="justify"><span style="color: #000000;"><strong>1. Видът на замърсената повърхност: </strong>замърсените повърхности биват 4 вида:</span></p>
<p align="justify"><span style="color: #000000;">- кожа на човешкото тяло,</span></p>
<p align="justify"><span style="color: #000000;">- повърхности, в непосредствен контакт с кожата (бельо, кърпи за изтриване пр.), </span></p>
<p align="justify"><span style="color: #000000;">- замърсени повърхности, в близост до тялото (работно облекло, обувки, маски и др.) и</span></p>
<p align="justify"><span style="color: #000000;">- всички други повърхности (предмети, плотове, стени и др.).</span></p>
<p align="justify"><span style="color: #000000;"><strong>2. Видът на радиоактивния замърсител</strong>: α- или β- емитер; енергиен спектър на радионуклида-замърсител; физикохимическите характеристики (течност или прах, вид на съединението).</span></p>
<p align="justify"><span style="color: #000000;"><strong>3. Видът на самото замърсяване</strong>: трайно фиксирано върху повърхността; нефиксирано, което може да бъде почистено или и двата вида едновременно.</span></p>
<p><span style="color: #000000;"> </span></p>
<h3><span style="text-decoration: underline;"><strong><span style="color: #000000; text-decoration: underline;">Основни понятия</span></strong></span></h3>
<p align="justify"><strong style="color: #000000;">Повърхностно замърсяване:</strong><span style="color: #000000;"> Замърсяване на повърхностите с радиоактивни вещества.</span></p>
<ul>
<li><strong style="color: #000000;">Фиксирано повърхностно   замърсяване: </strong><span style="color: #000000;">  Замърсяване,   прилепнало   към повърхността по такъв начин, че е невъзможно да се отстрани в нормални работни условия;</span></li>
<li><strong style="color: #000000;">Нефиксирано повърхностно замърсяване:</strong><span style="color: #000000;"> Повърхностно замърсяване, което може да се отстрани или трансферира при нормални работни условия.</span></li>
</ul>
<p align="justify"><strong style="color: #000000;">Активност на единица площ:</strong><span style="color: #000000;"> Отношение между активността на радионуклидите,</span></p>
<p align="justify"><span style="color: #000000;"> присъстващи на повърхността, и площта на повърхността. Изразява се в  (Bq.cm<sup>-2</sup>).</span></p>
<p align="justify"><strong style="color: #000000;">Скорост</strong><strong style="color: #000000;">на излъчване на частици от повърхност (поток частици), </strong><strong style="color: #000000;">q</strong><strong style="color: #000000;"><sub>2</sub></strong><strong style="color: #000000;"><sub>p</sub></strong><span style="color: #000000;"> /surface emission rate of a source/:</span><strong style="color: #000000;"> </strong><span style="color: #000000;">Броят частици от даден вид и над определена енергия, които се излъчват от повърхността на източника за единица време. Единицата за скорост на излъчване на частици от повърхността на радиоактивния източник е: s</span><sup style="color: #000000;">-1</sup></p>
<p align="justify"><strong style="color: #000000;">Ефективност на инструмента</strong><strong style="color: #000000;">, </strong><strong style="color: #000000;">e</strong><strong style="color: #000000;"><sub>I</sub></strong><strong style="color: #000000;">:</strong><span style="color: #000000;"> Отношението между показанията на уреда (импулси за единица време) и скоростта на излъчване на частици от повърхността на радиоактивния източник (частици за единица време) при определени геометрични условия.</span></p>
<p align="justify"><span style="color: #000000;"><strong>Калибровъчният фактор на радиометър, </strong><strong>k<sub>R</sub></strong><strong>: <sub> </sub>1/</strong><strong>e</strong><strong><sub>I</sub></strong></span></p>
<p align="justify"><span style="color: #000000;"><strong>Ефективност на източника, </strong><strong>e</strong><strong>s</strong>: отношение на броя частици от даден тип с</span><br />
<span style="color: #000000;"> енергия над дадената, излъчени от предната повърхност на източника за единица време, към броя частици от същия тип, създавани или изпускани в източника (за тънък източник), или към дебелината на неговия слой на насищане (за източник с дебелина) за единица време.</span></p>
<p><span style="color: #000000;"> </span></p>
<h3><span style="text-decoration: underline;"><strong><span style="color: #000000; text-decoration: underline;">Методи за измерване</span></strong></span></h3>
<p align="justify"><span style="color: #000000;">Повърхностното замърсяване може да бъде оценено с помощта на директен и индиректен метод на измерване.</span></p>
<p align="justify"><strong style="color: #000000;"><em>Директните измервания</em></strong><span style="color: #000000;"> се провеждат с монитори (радиометри) за повърхностното замърсяване, които измерват нефиксираното плюс фиксираното повърхностно замърсяване.</span></p>
<p align="justify"><strong style="color: #000000;"><em>Индиректното измерване</em></strong><span style="color: #000000;"> като правило се провежда по метода на намазките, с помощта на който се определя само нефиксираното повърхностно замърсяване.</span></p>
<p align="justify"><span style="color: #000000;">Директните измервания са особено трудни или невъзможни, ако върху повърхността присъства неактивна течност или твърди отлагания, или ако има влияещо радиационно поле. </span></p>
<p align="justify"><span style="color: #000000;">Индиректният метод е по-широко приложим, особено когато повърхностите са труднодостъпни за измерване поради разположението или конфигурацията си, или когато влияещите радиационни полета въздействат върху мониторите за замърсяване.</span></p>
<p>&nbsp;</p>
<h5><span style="color: #000000;"><em>Автор: Станислав Станев</em></span><span style="color: #000000;"> </span></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/surface_radioactive_contamination/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Радиоактивност или радиация?</title>
		<link>http://metroion.com/radioactivity_or_radiation/</link>
		<comments>http://metroion.com/radioactivity_or_radiation/#comments</comments>
		<pubDate>Wed, 07 Nov 2012 07:21:39 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Величини и единици]]></category>
		<category><![CDATA[алфа-частици]]></category>
		<category><![CDATA[бета-частици]]></category>
		<category><![CDATA[гама-лъчи]]></category>
		<category><![CDATA[изотопи]]></category>
		<category><![CDATA[йонизираща радиация]]></category>
		<category><![CDATA[йонизиращо излъчване]]></category>
		<category><![CDATA[йонизиращо лъчение]]></category>
		<category><![CDATA[радиация]]></category>
		<category><![CDATA[радиоактивност]]></category>

		<guid isPermaLink="false">http://metroion.com/?p=1499</guid>
		<description><![CDATA[Тези две понятия се използват едновременно от всички, но без да се замисля човек, дали има разлика между тях. Думата „радиоактивност” се използва в професионалните среди, а думата „радиация” се използва масово от населението. Ето и техните определения в Уикипедия:  Радиоактивност (от латински radio — излъчвам, и activus — действен) се нарича способността на атомните ядра на нестабилни изотопи на химични елементи да се превръщат спонтанно<a href="http://metroion.com/radioactivity_or_radiation/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;">Тези две понятия се използват едновременно от всички, но без да се замисля човек, дали има разлика между тях. Думата „радиоактивност” се използва в професионалните среди, а думата „радиация” се използва масово от населението. Ето и техните определения в</span> <a title="Уикипедия" href="http://bg.wikipedia.org/wiki/%D0%9D%D0%B0%D1%87%D0%B0%D0%BB%D0%BD%D0%B0_%D1%81%D1%82%D1%80%D0%B0%D0%BD%D0%B8%D1%86%D0%B0" target="_blank">Уикипедия</a>:<strong> </strong></p>
<p align="justify"><span style="color: #000000;"><strong>Радиоактивност</strong> (от </span><a title="Латински" href="http://bg.wikipedia.org/wiki/%D0%9B%D0%B0%D1%82%D0%B8%D0%BD%D1%81%D0%BA%D0%B8">латински</a> <span style="color: #000000;">radio — <em>излъчвам</em>, и activus — <em>действен</em>) се нарича способността на</span> <a title="Атомно ядро" href="http://bg.wikipedia.org/wiki/%D0%90%D1%82%D0%BE%D0%BC%D0%BD%D0%BE_%D1%8F%D0%B4%D1%80%D0%BE">атомните ядра</a> <span style="color: #000000;">на нестабилни </span><a title="Изотоп" href="http://bg.wikipedia.org/wiki/%D0%98%D0%B7%D0%BE%D1%82%D0%BE%D0%BF">изотопи</a> <span style="color: #000000;">на</span> <a title="Химичен елемент" href="http://bg.wikipedia.org/wiki/%D0%A5%D0%B8%D0%BC%D0%B8%D1%87%D0%B5%D0%BD_%D0%B5%D0%BB%D0%B5%D0%BC%D0%B5%D0%BD%D1%82">химични елементи</a> <span style="color: #000000;">да се превръщат спонтанно в ядра на други химични елементи, при което се излъчва </span><a title="Енергия" href="http://bg.wikipedia.org/wiki/%D0%95%D0%BD%D0%B5%D1%80%D0%B3%D0%B8%D1%8F">енергия</a> <span style="color: #000000;">във формата на електромагнитно лъчение или</span> <a title="Елементарна частица" href="http://bg.wikipedia.org/wiki/%D0%95%D0%BB%D0%B5%D0%BC%D0%B5%D0%BD%D1%82%D0%B0%D1%80%D0%BD%D0%B0_%D1%87%D0%B0%D1%81%D1%82%D0%B8%D1%86%D0%B0">частици</a> - <span style="color: #000000;">например </span><a title="Алфа-частици" href="http://bg.wikipedia.org/wiki/%D0%90%D0%BB%D1%84%D0%B0-%D1%87%D0%B0%D1%81%D1%82%D0%B8%D1%86%D0%B8">алфа-частици</a>, <a title="Бета-частици" href="http://bg.wikipedia.org/wiki/%D0%91%D0%B5%D1%82%D0%B0-%D1%87%D0%B0%D1%81%D1%82%D0%B8%D1%86%D0%B8">бета-частици</a> <span style="color: #000000;">или</span> <a title="Гама-лъчи" href="http://bg.wikipedia.org/wiki/%D0%93%D0%B0%D0%BC%D0%B0-%D0%BB%D1%8A%D1%87%D0%B8">гама-лъчи</a> <span style="color: #000000;">(източник Уикипедия).</span></p>
<p align="justify"><span style="color: #000000;"><strong>Радиация</strong> (на </span><a title="Английски език" href="http://bg.wikipedia.org/wiki/%D0%90%D0%BD%D0%B3%D0%BB%D0%B8%D0%B9%D1%81%D0%BA%D0%B8_%D0%B5%D0%B7%D0%B8%D0%BA">английски</a><span style="color: #000000;">: <em>radiation</em>) означава излъчване на вълни или частици, но на</span> <a title="Български език" href="http://bg.wikipedia.org/wiki/%D0%91%D1%8A%D0%BB%D0%B3%D0%B0%D1%80%D1%81%D0%BA%D0%B8_%D0%B5%D0%B7%D0%B8%D0%BA">български</a> <span style="color: #000000;">под радиация най-често се разбира <strong>йонизираща </strong><strong>радиация</strong> със </span><a title="Синоним" href="http://bg.wikipedia.org/wiki/%D0%A1%D0%B8%D0%BD%D0%BE%D0%BD%D0%B8%D0%BC">синоними</a> <span style="color: #000000;"><strong>йонизиращо лъчение</strong> и <strong>йонизиращо излъчване </strong>(източник Уикипедия).</span></p>
<p align="justify"><span style="color: #000000;">В действителност английската дума „<strong>radiation</strong>” не е коректно да се превежда директно, т.е. &#8220;радиация&#8221;, тъй като тази дума означава &#8220;излъчване&#8221;. Ето защо думата &#8220;радиация&#8221; се използва само от населението, но не и от занимаващите се професионално хора в тази област.</span></p>
<p align="justify"><span style="color: #000000;">В крайна сметка <strong>Радиоактивност (radioactivity) </strong>и<strong> Радиация </strong><strong>(</strong><strong>radiation</strong><strong>)</strong> са различни думи, описващи един и същ процес, а именно способността на </span><a title="Атомно ядро" href="http://bg.wikipedia.org/wiki/%D0%90%D1%82%D0%BE%D0%BC%D0%BD%D0%BE_%D1%8F%D0%B4%D1%80%D0%BE">атомните ядра</a> <span style="color: #000000;">на нестабилни </span><a title="Изотоп" href="http://bg.wikipedia.org/wiki/%D0%98%D0%B7%D0%BE%D1%82%D0%BE%D0%BF">изотопи</a> <span style="color: #000000;">на</span> <a title="Химичен елемент" href="http://bg.wikipedia.org/wiki/%D0%A5%D0%B8%D0%BC%D0%B8%D1%87%D0%B5%D0%BD_%D0%B5%D0%BB%D0%B5%D0%BC%D0%B5%D0%BD%D1%82">химични елементи</a> <span style="color: #000000;">да се превръщат спонтанно в ядра на други химични елементи, при което се излъчва</span> <a title="Енергия" href="http://bg.wikipedia.org/wiki/%D0%95%D0%BD%D0%B5%D1%80%D0%B3%D0%B8%D1%8F">енергия</a><span style="color: #000000;">.</span></p>
<h5><span style="color: #000000;"><strong><em>Автор: Росен Иванов  </em>  </strong></span></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/radioactivity_or_radiation/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Купуване на дозиметър или радиометър?</title>
		<link>http://metroion.com/buying-dosimeter_and_radiometer/</link>
		<comments>http://metroion.com/buying-dosimeter_and_radiometer/#comments</comments>
		<pubDate>Mon, 22 Oct 2012 10:20:30 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Йонизиращи лъчения]]></category>
		<category><![CDATA[величина]]></category>
		<category><![CDATA[грешка]]></category>
		<category><![CDATA[дозиметър]]></category>
		<category><![CDATA[енергиен обхват]]></category>
		<category><![CDATA[обхват]]></category>
		<category><![CDATA[радиометър]]></category>

		<guid isPermaLink="false">http://metroion.com/?p=1441</guid>
		<description><![CDATA[Преди да си купите дозиметър или радиометър в областта на йонизиращите лъчения, трябва да сте наясно за какво ще го използвате. След като знаете къде и за какво ще го използвате е необходимо да прецените какъв обхват на измерване ви е необходим, каква величина ще измервате (обикновено еквивалентна доза за дозиметър и скорост на излъчване<a href="http://metroion.com/buying-dosimeter_and_radiometer/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;">Преди да си купите дозиметър или радиометър в областта на йонизиращите лъчения, трябва да сте наясно за какво ще го използвате. След като знаете къде и за какво ще го използвате е необходимо да прецените какъв обхват на измерване ви е необходим, каква величина ще измервате (обикновено еквивалентна доза за дозиметър и скорост на излъчване на частици за радиометър), каква грешка на измерване има уреда и т.н. Днес повечето дозиметри и радиометри измерват в доста широки граници, като това което търсите ще определите вие според нуждите ви. Ако се затруднявате, по-добре е да използвате посредник, като това ще ви спести много главоболия (вижте страница &#8220;<a title="Фирми" href="http://metroion.com/organizations/companies_in_metrology/" target="_blank">Фирми</a>&#8220;).<span id="more-1441"></span></span></p>
<p><span style="color: #000000;">Ще структурирам стъпките  при закупуването на уреда:</span></p>
<p align="justify"><strong><span style="color: #000000;">1. Преценете добре за какво ще използвате уреда, за да не се окаже, че сте дали няколко хиляди лева за неизползваемо средство за измерване.</span></strong><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;">Едни от най-важните характеристики са:</span></p>
<p><span style="color: #000000;">  &#8211;   величина на измерване (обикновено поддържат няколко);</span></p>
<p><span style="color: #000000;">  &#8211;   обхват на измерване;</span></p>
<p><span style="color: #000000;">  &#8211;   енергиен обхват на измерване;</span></p>
<p><span style="color: #000000;">  &#8211;   грешка на измерване.</span><span style="color: #000000;"> </span></p>
<p align="justify"><span style="color: #000000;"><span style="text-decoration: underline;">Важно</span>: Ако си закупите комбиниран уред за измерване, ще икономисате пари, т.е. това са уреди работещи едновременно като дозиметри и радиометри, с помощта на подходящ набор от детектори.</span></p>
<p><strong><span style="color: #000000;">2. Проверете уреда, който желаете дали е от одобрен тип.</span></strong></p>
<p align="justify"><span style="color: #000000;">Това можете да го направите в сайта на <a title="Българския Институт по Мтерология" href="http://www.bim.government.bg/" target="_blank">Българския Институт по Мтерология</a>, тъй като той е отговорен за одобряването на типовете уреди за измерване. Отидете към Регистъра <a title="РЕГИСТЪР" href="http://www.bim.government.bg/BIM/bim.nsf/index.xsp?page=ABF79904533B9B59C225789400225C63" target="_blank">»»»»»</a> </span></p>
<p align="justify"><span style="color: #000000;"><span style="text-decoration: underline;">Важно</span>: Ако уреда не е от одобрен тип, по-добре не го купувайте, защото той ще е със статут „незаконен” и не подлежи на ежегодна проверка, като няма да можете да го използвате за измервания, които трябва да удостоверявате. Това означава, че ако имате работа с <a title="Агенция за Ядрено Регулиране" href="http://www.bnsa.bas.bg/" target="_blank">Агенцията за Ядрено Регулиране</a>, те няма да ви признаят резултатите от вашето измерване. По-друг начин седи въпроса с калибрирането. Там не е нужно уреда да е от одобрен тип. Калибрирането в България се извършва от Българския Институт по Мтерология в град Ловеч и се признава от <a title="Българска Служба по Акредитация" href="http://nab-bas.bg/bg" target="_blank">Българската Служба по Акредитация</a>.</span></p>
<p><strong><span style="color: #000000;">3. Бюджет.</span></strong></p>
<p align="justify"><span style="color: #000000;">След като сте наясно с положенията описани по-горе и знаете с какъв бюджет разполагате, трябва да проучите какви уреди има на пазара, които покриват вашите изисквания, посочени в точка 1. Може да използвате страницата „</span><a style="color: #ff4500;" title="Фирми" href="http://metroion.com/organizations/companies_in_metrology/" target="_blank">Фирми</a><span style="color: #000000;">” и да отправите запитване към тях, които от своя страна трябва да ви изготвят оферта. Така ще прецените кое е най-изгодно за вас.</span></p>
<p align="justify"><span style="color: #000000;">Ако разполагате със скромен бюджет трябва да си купите уред от някоя страна от бившата СССР, но не ви го препоръчвам. Опита, които имам с различни видове уреди ми е показал, че уредите произведени в Западна Европа, потвърждават много по-добре характеристиките си, посочени от производителя.</span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"><strong><span style="text-decoration: underline;">Препоръчани дозиметри, радиометри или комбинирани</span></strong><strong><span style="text-decoration: underline;"> уреди</span></strong><strong>:</strong></span></p>
<p style="text-align: left;"><span style="text-align: center;">                                                                                          </span><span style="text-align: center;">                          </span></p>
<p><span style="color: #000000;"><img class="alignleft size-full wp-image-1446" title="FH 40 G" src="http://metroion.com/wp-content/uploads/2012/10/FH-40-G.jpg" alt="FH 40 G " width="130" height="256" /><span style="text-align: center;">FH 40 G                               </span></span></p>
<p style="padding-left: 120px;"><span style="color: #000000;"><span style="text-align: center;">                   InSpector™ 1000  </span><span style="text-align: center;"> </span><img class="size-full wp-image-1447" style="border: 1px solid black;" title="InSpector™ 1000" src="http://metroion.com/wp-content/uploads/2012/10/InSpector™-1000.jpg" alt="" width="160" height="221" /></span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span><span style="color: #000000;"><span style="text-align: center;">       </span></span><span style="text-align: center; color: #000000;"> </span><span style="text-align: center;"> </span><span style="color: #000000; text-align: center;">         </span><span style="color: #000000;"> </span><span style="color: #000000; text-align: center;">                               </span></p>
<p><span style="color: #000000;"><span style="color: #000000;"><img class="size-full wp-image-1450 alignleft" style="border: 1px solid black;" title="Radiagem 2000" src="http://metroion.com/wp-content/uploads/2012/10/Radiagem-2000.jpg" alt="" width="171" height="189" /></span><span style="text-align: center;">Radiagem™-2000/4000</span>             </span></p>
<p><span style="color: #000000;">              </span><span style="color: #000000; text-align: center;">Berthold LB 123 D</span><span style="color: #000000;"> </span><img class="size-full wp-image-1449" style="border: 1px solid black;" title="Berthold LB 123 D" src="http://metroion.com/wp-content/uploads/2012/10/Berthold-LB-123-D.jpg" alt="" width="134" height="201" /></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span><span style="color: #000000; text-align: center;">                                       </span></p>
<p><span style="color: #000000; text-align: center;">              </span><span style="color: #000000;"> </span><span style="color: #000000;">   </span><span style="color: #000000; text-align: center;">                             </span></p>
<p><span style="color: #000000;"><span style="color: #000000;"><img class="alignleft size-full wp-image-1451" style="border: 1px solid black;" title="RDS-110" src="http://metroion.com/wp-content/uploads/2012/10/RDS-110.jpg" alt="" width="145" height="145" /></span></span><span style="color: #000000; text-align: center;">RDS-110</span><span style="color: #000000;">                   </span></p>
<p><span style="color: #000000;">           Automess 6150AD</span><span style="color: #000000;">  </span><img class="size-full wp-image-1448" style="line-height: 19px; border: 1px solid black;" title="Automess 6150AD" src="http://metroion.com/wp-content/uploads/2012/10/Automess-6150AD.jpg" alt="" width="199" height="192" /></p>
<p><span style="text-align: center; color: #000000;">  </span></p>
<h5><span style="color: #000000;"><strong><em>Автор: Росен Иванов  </em>  </strong></span></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/buying-dosimeter_and_radiometer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Методи за измерване в дозиметрията</title>
		<link>http://metroion.com/method-measuring-in-dosimetry/</link>
		<comments>http://metroion.com/method-measuring-in-dosimetry/#comments</comments>
		<pubDate>Fri, 28 Sep 2012 11:33:48 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Област Дозиметрия]]></category>
		<category><![CDATA[дозиметрия]]></category>
		<category><![CDATA[дозиметър]]></category>
		<category><![CDATA[измерване]]></category>
		<category><![CDATA[калибриране]]></category>
		<category><![CDATA[методи]]></category>
		<category><![CDATA[сравнение]]></category>

		<guid isPermaLink="false">http://localhost/MetroIon/?p=1162</guid>
		<description><![CDATA[Калибрирането се извършва по метода на: сравнение; заместване; преки измервания; едновременното измерване; абсолютното измерване. Въведение Като цяло, референтните инструменти не измерват пряко подходящите еквивалентни величини за калибриране или изпитване. Вместо това, най-често референтните инструменти се използват за характеризиране на радиационни полета чрез други измервателни величини като въздушна керма за фотонно лъчение. Величината еквивалентна доза се получава от основни<a href="http://metroion.com/method-measuring-in-dosimetry/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p><span style="color: #000000;"><strong>Калибрирането се извършва по метода на:</strong></span></p>
<ul>
<li><span style="color: #000000;">сравнение;</span></li>
<li><span style="color: #000000;">заместване;</span></li>
<li><span style="color: #000000;">преки измервания;</span></li>
<li><span style="color: #000000;">едновременното измерване;</span></li>
<li><span style="color: #000000;">абсолютното измерване.</span></li>
</ul>
<p><span style="color: #000000;"><strong>Въведение</strong></span></p>
<p align="justify"><span style="color: #000000;">Като цяло, референтните инструменти не измерват пряко подходящите еквивалентни величини за калибриране или изпитване. Вместо това, най-често референтните инструменти се използват за характеризиране на радиационни полета чрез други измервателни величини като въздушна керма за фотонно лъчение. Величината еквивалентна доза се получава от основни радиационни величини с подходящи коефициенти за преобразуване.<span id="more-1162"></span></span></p>
<p align="justify"><span style="color: #000000;">Трябва да се направи разграничение между четири метода на калибриране, които могат да бъдат използвани. Ако се използва референтен инструмент (обозначен с долно R по-надолу), калибрационния фактор, N<sub>R</sub>, даден в сертификата за калибриране, може да се използва, за да се определи истинската стойност на еквивалентната доза H с помощта на конверсионния коефициент h за еквивалентната доза H и измерената M<sub>R </sub>стойност на референтния инструмент (коригирани за референтни условия):</span></p>
<p style="text-align: center;" align="justify"><span style="color: #000000;"><img class="aligncenter  wp-image-1168" title="Dose" src="http://metroion.com/wp-content/uploads/2012/09/Dose2.jpg" alt="" /></span></p>
<p style="text-align: left;"><span style="color: #000000;">(а) където референтния инструмент отчита една и съща измервана величина, както инструмента, подлежащ на калибриране:</span></p>
<p style="text-align: center;"><span style="color: #000000;"> h = 1</span></p>
<p align="justify"><span style="color: #000000;">(б) когато референтния инструмент показва величина, различна от тази на инструмента, подлежащ на калибриране. Тук трябва да се прилага подходящ конверсионнен коефициент h.</span></p>
<p style="text-align: center;"><span style="color: #000000;"> </span></p>
<h5 style="text-align: center;"><span style="color: #000000;"><span style="color: #000000;"><img class="aligncenter  wp-image-1174" style="border: black 1px solid;" title="Calibration methods" src="http://metroion.com/wp-content/uploads/2012/09/Calibration-methods.jpg" alt="" width="537" height="744" /></span><em>Четири метода за калибриране.  Метод 1:  Калибриране с референтен инструмент без монитор; Метод 2: Калибриране с референтен инструмент с монитор; Метод 3: Калибриране чрез заместване; Метод 4: Калибриране в познато радиационно поле.</em></span></h5>
<p style="text-align: left;"><span style="color: #000000;">  </span></p>
<p align="justify"><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Измервания без монитор на изхода на източника (Метод на калибриране 1)</strong></span></span></p>
<p align="justify"><span style="color: #000000;">Тази процедура е подходяща, ако стойността на физична величина, характеризираща радиационното поле (напр. мощност на въздушната керма) е стабилна в продължение на период от време, съответстваща на продължителността на калибрирането, до степента, до която са постигнати резултатите от желаната точност. Калибрирането се извършва при стандартни тестови условия, близки до референтните условия. Референтните точки на референтния инструмент и инструмента, подлежащ на калибриране впоследствие се позиционират на мястото на теста на радиационното поле за калибриране по отношение на величината еквивалентна доза H.</span></p>
<p align="justify"><span style="color: #000000;">За референтните инструмент (долен R), се получава (1):</span></p>
<p style="text-align: center;"><span style="color: #000000;"><img class="size-full wp-image-1186 aligncenter" title="1" src="http://metroion.com/wp-content/uploads/2012/09/1.jpg" alt="" width="86" height="42" /></span><span style="color: #000000;">и за инструмента подлежащ на калибриране (долен I), чиято индикация е пряко свързана с величината еквивалентна доза H, получаваме (2):</span></p>
<p style="text-align: center;"> <img class="aligncenter size-full wp-image-1187" title="2" src="http://metroion.com/wp-content/uploads/2012/09/2.jpg" alt="" width="67" height="42" /></p>
<p align="center"><span style="color: #000000;">                                 </span></p>
<p align="justify"><span style="color: #000000;">Комбинацията от двете формули (1) и (2) по-горе ни дават калибрационния фактор N<sub>I</sub>:</span></p>
<p style="text-align: center;"> <img class="aligncenter size-full wp-image-1192" title="1-2" src="http://metroion.com/wp-content/uploads/2012/09/1-2.jpg" alt="" width="105" height="42" /></p>
<p><span style="color: #000000;">където:</span></p>
<p><span style="color: #000000;">N<sub>R</sub> е калибрационния фактор на референтния инструмент (при референтни условия);</span></p>
<p><span style="color: #000000;">N<sub>I </sub>е калибрационния фактор на инструмента подлежащ на калибриране (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">M<sub>R</sub> е измерената стойност от референтния инструмент, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p align="justify"><span style="color: #000000;">М<sub>I</sub> е измерената стойност от инструмента подлежащ на калибриране, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p><span style="color: #000000;">h е конверсионния коефициент.</span></p>
<p>&nbsp;</p>
<p><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Измервания с монитор на изхода на източника (Метод на калибриране 2)</strong></span></span></p>
<p align="justify"><span style="color: #000000;">Умерените вариации във физическите величини, които характеризират дозиметричените свойства на радиационно поле (например мощност на въздушната керма) с течение на времето могат да бъдат коригирани последователно с помощта на монитор и от облъчването на референтния инструмент и инструмента, подлежащ на калибриране. Тази техника често се използва в рентгеновата област с цел да се коригира вариацията на мощността на въздушната керма, когато последователно референтния инструмент и инструмента, подлежащ на калибриране се поставят на мястото на измерване.</span></p>
<p align="justify"><span style="color: #000000;">Величината еквивалентна доза H в точката на измерване е свързана с калибрационния </span><span style="color: #000000;">фактор на камерата на монитора, N<sub>M</sub>, и измерените стойности m чрез <span style="color: #000000;">(3)</span></span></p>
<p style="text-align: center;" align="justify"><span style="color: #000000;"> </span> <img class="aligncenter size-full wp-image-1188" title="3" src="http://metroion.com/wp-content/uploads/2012/09/3.jpg" alt="" width="65" height="35" /></p>
<p style="text-align: center;" align="justify"><span style="color: #000000;">Съответните уравнения за референтния инструмент и инструмента, подлежащ на калибриране са  (4) <span style="color: #000000;">и (5)</span>:</span> <span style="color: #000000;">   <img class="aligncenter size-full wp-image-1189" title="4" src="http://metroion.com/wp-content/uploads/2012/09/4.jpg" alt="" width="80" height="42" /><img class="aligncenter size-full wp-image-1190" title="5" src="http://metroion.com/wp-content/uploads/2012/09/5.jpg" alt="" width="64" height="40" /></span></p>
<p style="text-align: left;"><span style="color: #000000;">Величината H може да бъде елиминирана в уравнения (4) и (5) с помощта на уравнение (3), като получаваме (6) и (7):</span></p>
<p style="text-align: center;"> <img class="aligncenter size-full wp-image-1191" title="6" src="http://metroion.com/wp-content/uploads/2012/09/6.jpg" alt="" width="100" height="42" /></p>
<p style="text-align: center;" align="center"><span style="color: #000000;">         <img class="aligncenter size-full wp-image-1193" title="7" src="http://metroion.com/wp-content/uploads/2012/09/7.jpg" alt="" width="92" height="42" />           </span></p>
<p style="text-align: left;"><span style="color: #000000;">Разделяйки уравнение (7) на уравнение (6) се довежда до премахване на калибрационния фактор N<sub>M</sub> и получаваме за N<sub>I</sub>:   </span><span style="color: #000000;"> </span></p>
<p style="text-align: center;"> <img class="aligncenter size-full wp-image-1194" title="6-7" src="http://metroion.com/wp-content/uploads/2012/09/6-7.jpg" alt="" width="159" height="42" /></p>
<p><span style="color: #000000;">където</span></p>
<p style="text-align: left;"><span style="color: #000000;">N<sub>R</sub> е калибрационния фактор на референтния инструмент (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">N<sub>I </sub>е калибрационния фактор на инструмента подлежащ на калибриране (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">M<sub>R</sub> е измерената стойност от референтния инструмент, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p align="justify"><span style="color: #000000;">М<sub>I</sub> е измерената стойност от инструмента подлежащ на калибриране, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p align="justify"><span style="color: #000000;">m<sub>R</sub> е измерената стойност на монитора за облъчването на референтния инструмент, коригирана за референтни условия;</span></p>
<p align="justify"><span style="color: #000000;">m<sub>I</sub> е измерената стойност на монитора за облъчването на инструмента, подлежащ на калибриране, коригирана за референтни условия;</span></p>
<p><span style="color: #000000;">h е конверсионния коефициент.</span></p>
<p>&nbsp;</p>
<p align="justify"><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Калибриране чрез едновременно облъчване на двата дозиметъра (Метод на калибриране 3)</strong></span></span></p>
<p align="justify"><span style="color: #000000;">В някои случаи калибрирането може да се извършва чрез едновременно облъчване на детекторите на референтния инструмент и инструмент подлежащ на калибриране, като се поставят симетрично на оста на радиационно поле, на едно и също разстояние от източника. Разстоянието между двата детектора трябва да бъде достатъчно голямо, за да не  бъде повлияна от присъствието на другия инструмент.</span></p>
<p align="justify"><span style="color: #000000;">На първо място, тази процедура ще се прилага за тези случаи, когато не е необходимо да има фантом. Тази техника се използва особено за референтни радиационни процедури от ускорители или при използване на неколимирани източници.</span></p>
<p align="justify"><span style="color: #000000;">Мощността на еквивалентната доза H при две симетрични точки на калибриране е свързана с калибрационния фактор на референтния инструмент в точката на калибриране №1,<em> (8)</em>:</span></p>
<p style="text-align: center;" align="justify"> <img class="aligncenter size-full wp-image-1197" title="8" src="http://metroion.com/wp-content/uploads/2012/09/8.jpg" alt="" width="103" height="44" /><span style="color: #000000;">както и в точка на калибриране № 2 на инструмента подлежащ на калибриране (9),</span></p>
<p style="text-align: center;">  <img class="aligncenter size-full wp-image-1198" title="9" src="http://metroion.com/wp-content/uploads/2012/09/9.jpg" alt="" width="87" height="44" /></p>
<p align="center"><span style="color: #000000;">              </span></p>
<p style="text-align: left;"><span style="color: #000000;">За да се премахне влиянието на асиметрия на радиационното поле, измерванията се повтарят след размяна на позициите на двата инструмента, ние получаваме (10) и  (11)</span></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-1199" title="10" src="http://metroion.com/wp-content/uploads/2012/09/10.jpg" alt="" width="103" height="44" /></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-1200" title="11" src="http://metroion.com/wp-content/uploads/2012/09/11.jpg" alt="" width="87" height="44" /></p>
<p align="justify"><span style="color: #000000;">H<sub>1</sub> и H<sub>2</sub> могат да бъдат елиминирани чрез комбиниране на уравненията (8) и (11), и уравненията (9) и (10), съответно (12) и (13):</span></p>
<p style="text-align: center;"> <span style="color: #000000;">                 <img class="aligncenter size-full wp-image-1202" title="12" src="http://metroion.com/wp-content/uploads/2012/09/12.jpg" alt="" width="103" height="44" />      <img class="aligncenter size-full wp-image-1203" title="13" src="http://metroion.com/wp-content/uploads/2012/09/13.jpg" alt="" width="103" height="44" /></span></p>
<p style="text-align: left;"><span style="color: #000000;">Умножаването на уравненията (12) и (13) води до</span></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-1204" title="12-13" src="http://metroion.com/wp-content/uploads/2012/09/12-13.jpg" alt="" width="202" height="62" /></p>
<p><span style="color: #000000;">където</span></p>
<p style="text-align: left;"><span style="color: #000000;">N<sub>R</sub> е калибрационния фактор на референтния инструмент (при референтни условия);</span></p>
<p><span style="color: #000000;">N<sub>I </sub>е калибрационния фактор на инструмента подлежащ на калибриране (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">(M<sub>R</sub>/M<sub>I</sub>)<sub>1 </sub>е измерената стойност на референтния инструмент, разделена на съответната стойност на инструмента, подлежащ на калибриране в точка за калибриране № 1, коригирани за референтни условия;</span></p>
<p align="justify"><span style="color: #000000;">(M<sub>R</sub>/M<sub>I</sub>)<sub>2 </sub>е измерената стойност на референтния инструмент, разделена на съответната стойност на инструмента, подлежащ на калибриране в точка за калибриране № 2, коригирани за референтни условия;</span></p>
<p style="text-align: left;"><span style="color: #000000;">h е конверсионния коефициент.</span></p>
<p style="text-align: left;"><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Калибриране в познато радиационно поле (Метод на калибриране 4)</strong></span></span></p>
<p align="justify"><span style="color: #000000;">За радиационното поле, за което е известно стойността на еквивалентната доза H в точката на калибриране, калибрирационния фактор на инструмента N<sub>I</sub>, се получава чрез</span></p>
<p style="text-align: center; padding-left: 60px;" align="center"><span style="color: #000000;">N<sub>I</sub> = H / M<sub>I</sub>                     (14)</span></p>
<p style="text-align: left;"><span style="color: #000000;">където</span></p>
<p align="justify"><span style="color: #000000;">N<sub>I </sub>е калибрационния фактор на инструмента подлежащ на калибриране (при референтни условия);</span></p>
<p align="justify"><span style="color: #000000;">М<sub>I</sub> е измерената стойност от инструмента, подлежащ на калибриране, коригирана за референтни условия, т.е. умножена с приложимите фактори за корекция (например за разликите за температура и налягане);</span></p>
<p align="justify"><span style="color: #000000;">H е истинската стойност на еквивалентната доза, която се измерва.</span></p>
<p>&nbsp;</p>
<h5><span style="color: #000000;"><em><strong>Автор: Росен Иванов</strong></em></span></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/method-measuring-in-dosimetry/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Осигуряване на проследимост в метрологията</title>
		<link>http://metroion.com/traceability-in-metrology/</link>
		<comments>http://metroion.com/traceability-in-metrology/#comments</comments>
		<pubDate>Wed, 26 Sep 2012 05:53:42 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Категории]]></category>
		<category><![CDATA[Метрология]]></category>
		<category><![CDATA[еталон]]></category>
		<category><![CDATA[измерване]]></category>
		<category><![CDATA[калибриране]]></category>
		<category><![CDATA[методи]]></category>
		<category><![CDATA[метрологична инфраструктура]]></category>
		<category><![CDATA[национален еталон]]></category>
		<category><![CDATA[сравнение]]></category>

		<guid isPermaLink="false">http://localhost/MetroIon/?p=1101</guid>
		<description><![CDATA[Националната система за измерване се разглежда по същество като национална инфраструктура, която обслужва много от критичните аспекти на обществото. Тя е рамката, в която Националният център по метрология e източник на проследимост в страната, като поддържа националните еталони и разпространява реализираните от тях стойности към ежедневните измервания в индустрията, търговията и услугите, за изследвания, за<a href="http://metroion.com/traceability-in-metrology/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;">Националната система за измерване се разглежда по същество като национална инфраструктура, която обслужва много от критичните аспекти на обществото. Тя е рамката, в която Националният център по метрология e източник на проследимост в страната, като поддържа националните еталони и разпространява реализираните от тях стойности към ежедневните измервания в индустрията, търговията и услугите, за изследвания, за нужди на държавните и изпълнителните органи, във всички региони на страната, чрез непрекъсната верига от сравними измервания с обявена неопределеност. Това  е инфраструктурата, която осигурява за измерванията в България валидност, пригодност за използване и международно признаване.<span id="more-1101"></span></span></p>
<p align="justify"><span style="color: #000000;"><strong>Еталоните</strong> са уреди, системи или комплекси, който възпроизвеждат и съхраняват единиците на физичните величини и ги предават на други средства за измерване. Без еталони е невъзможно да се постигне съпоставимост на резултатите от измервания, извършени с различни уреди, на различни места и по различно време.</span></p>
<p align="justify"><span style="color: #000000;"><strong>Националните еталони </strong>на Република България са материалната връзка с международните еталони и основата за осигуряване на проследимост и точност на измерванията в страната.</span></p>
<p align="justify"><span style="color: #000000;">Състоянието на българските национални еталони засяга пряко развитието на области като законова метрология, акредитация, сертификация и оценяване на съответствието на продуктите с техническите изисквания към тях, и косвено влияе на конкурентноспособността на българските продукти и услуги и на качеството на живота в страната.</span></p>
<p align="justify"><span style="color: #000000;">Националната система за измервания е част от международната система. Политиката за единство на измерванията в световен мащаб се определя от Генералната конференция за мерки и теглилки (GCPM), в рамките на подписаната от правителствата Конвенция за метъра и се осъществява чрез регионалните метрологични организации (за Европа – EURAMET и СООМЕТ, в които Р България членува).</span></p>
<p align="justify"><span style="color: #000000;">През 1977 г. в България се основава Национален център по метрология със задача да създава и съхранява еталоните на страната.</span></p>
<p style="text-align: center;"><span style="color: #000000;"><strong>Схема на метрологичната инфраструктура</strong></span></p>
<p style="text-align: center;"><span style="color: #000000;"><a href="http://metroion.com/wp-content/uploads/2012/09/Traceability.jpg" target="_blank"><span style="color: #000000;"><img class="aligncenter  wp-image-1152" style="border: black 1px solid;" title="Traceability" src="http://metroion.com/wp-content/uploads/2012/09/Traceability.jpg" alt="" width="717" height="402" /></span></a></span></p>
<p align="justify"><span style="color: #000000;">Метрологията е техническата основа на инфраструктурата по качеството. Научната метрология е предпоставка за развитие на акредитацията, изпитванията и калибрирането.</span></p>
<p align="justify"><span style="color: #000000;">Законът за измерванията (обн., в ДВ, бр. 46 от 07.05.2002 г., последно изменение ДВ. бр.39 от 20.05.2011 г.) възлага създаването, съхраняването и усъвършенстването на националните еталони на  Република  България  на  БИМ  чрез  Главна  дирекция  “Национален център по метрология” (ГД НЦМ).</span></p>
<p align="justify"><span style="color: #000000;">В изпълнение на тази функция и в съответствие с политиката на правителството БИМ разработва “Дългосрочна програма за развитие на националните еталони на Република България”.</span></p>
<h5><span style="color: #000000;"><em><strong>Автор: Росен Иванов</strong></em></span></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/traceability-in-metrology/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Методи за измерване на активност на радионуклиди</title>
		<link>http://metroion.com/methods-measure-activity/</link>
		<comments>http://metroion.com/methods-measure-activity/#comments</comments>
		<pubDate>Mon, 24 Sep 2012 06:09:33 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Област Активност]]></category>
		<category><![CDATA[активност]]></category>
		<category><![CDATA[еталон]]></category>
		<category><![CDATA[измерване]]></category>
		<category><![CDATA[източник]]></category>
		<category><![CDATA[калибриране]]></category>
		<category><![CDATA[методи]]></category>
		<category><![CDATA[национален еталон]]></category>
		<category><![CDATA[радиоактивен]]></category>
		<category><![CDATA[радиоактивен източник]]></category>
		<category><![CDATA[радионуклиди]]></category>
		<category><![CDATA[сравнение]]></category>

		<guid isPermaLink="false">http://localhost/MetroIon/?p=1057</guid>
		<description><![CDATA[Същността и класификацията на методите за измерване на активност се основават на ясната представа за: -  Природата  на радиоактивното разпадане (всички описващи го параметри) на даден радионуклид и вида и характеристиките на съпътстващите го ЙЛ от една страна и; -  Всички възможни взаимодействия на тези ЙЛ с веществото на детектора и заобикалящата го среда от друга страна.<a href="http://metroion.com/methods-measure-activity/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;">Същността и класификацията на методите за измерване на активност се основават на ясната представа за:</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;">-  Природата  на радиоактивното разпадане (всички описващи го параметри) на даден радионуклид и вида и характеристиките на съпътстващите го ЙЛ от една страна и;</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;">-  Всички възможни взаимодействия на тези ЙЛ с веществото на детектора и заобикалящата го среда от друга страна.</span></p>
<p align="justify"><span style="color: #000000;">Радионуклидната метрология<em> </em>най-общо се занимава с радиоактивните вещества и техните количествени характеристики, основно величината активност.<span id="more-1057"></span></span></p>
<p align="justify"><span style="color: #000000;">Терминът <strong><em>радиоактивност </em></strong>се използва за описване на явлението на спонтанните ядрени превръщания, които се съпътстват от излъчването на <em>електромагнитни</em> или <em>корпускулярни</em> лъчения.</span></p>
<p align="justify"><span style="color: #000000;">Ядрените превръщания са <em>случаен процес</em> и се описват чрез експоненциалния закон за радиоактивно разпадане:</span></p>
<p style="padding-left: 120px;" align="justify"><span style="color: #000000;">                      <img class="size-full wp-image-1069 alignnone" title="Activity" src="http://metroion.com/wp-content/uploads/2012/09/Activity.png" alt="" width="97" height="26" /> </span><span style="color: #000000;">,   </span></p>
<p style="padding-left: 120px;" align="justify"><span style="color: #000000;">                       l=ln2<em> /</em>T<sub>1/2</sub>                                                                  </span></p>
<p><span style="color: #000000;">     </span><span style="color: #000000;">където:  </span></p>
<p><span style="color: #000000;">          N(t) – брой радиоактивни атоми в момента t ;</span></p>
<p><span style="color: #000000;">          N<sub>0</sub> – брой радиоактивни атоми в определен начален момент; </span></p>
<p><span style="color: #000000;">          l – константа на разпадането;</span></p>
<p><span style="color: #000000;">          T<sub>1/2</sub> – период на полуразпадане.</span></p>
<p align="justify"><span style="color: #000000;">Работата на всеки детектор на ЙЛ основно зависи от начина, по който изследваното лъчение взаимодейства с материала на самия детектор. Следователно познаването на отклика на определен тип детектор трябва да се основава на познаване на основните механизми, чрез които лъченията взаимодействат и губят енергията си във веществото.</span></p>
<p align="justify"><span style="color: #000000;">В зависимост от механизма на взаимодействие с веществото йонизиращите лъчения се делят на две групи:</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;">- <strong><em>Директно йонизиращи </em></strong><em>—</em> електрически заредени ча­стици (електрони, протони, алфа-частици и др.), която притежа­ват достатъчна кинетична енергия за йонизация чрез удар;</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;"><em>-<strong> Индиректно йонизиращи </strong></em><em>—</em> незаредени частици (фо­тон, неутрон и др.), която при взаимодействие с атомите на ве­ществото предизвикват получаване на директно йонизиращи частици или причиняват ядрено превръщане.</span></p>
<p align="justify"><span style="color: #000000;">Електрически заредените ча­стици  взаимодействат непрекъснато с електроните на веществото (чрез кулонови сили), като губят енергията си на малко порции в голям брой актове на взаимодействие.</span></p>
<p align="justify"><span style="color: #000000;">Това води до <em>йонизиране</em> или <em>възбуждане</em> на атомите, а съответните загуби на енергия на частицата обобщено се наричат <em>йонизационни загуби</em>.</span></p>
<p align="justify"><span style="color: #000000;">Електрически неутралните ча­стици не взаимодействат чрез кулонови сили с веществото, а посредством единични актове на взаимодействие, при които могат да възникнат заредени ча­стици с енерги, достатъчно висока за прдизвикване на йонизация.</span></p>
<p align="justify"><span style="color: #000000;">За създаването и прилагането на всеки един метод на измерване на активност е необходимо да се вземат предвид следнитве 3 основни факта:</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;">1) Всяка частица, която на взаимодейства с веществото на детектора на може да бъде регистрирана;</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;">2) Трябва винаги да се отчитат всички възможни взаимодействия на изучаваното ЙЛ както с чувствителния обем на детектора, така и с веществата, които го обкръжават;</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;">3) Всяка детектор на ЙЛ, регистрира не енергията на частицата, а само онази част от нея, която частицата е оставила в чувствителния обем на детектора. В редки случаи частицата оставя цялата си енергия в чувствителния обем на детектора.</span></p>
<p align="justify"><span style="color: #000000;">Познаването и отчитането на тези факти позволява да се предвидят и оценят всички ефекти, влияещи на резултата от дедено измерване и да се въведат съответните корекции за отчитането на всички или на някои от тези ефекти, когато е необходимо с цел постигането на желаната точност.</span></p>
<h2><span style="color: #000000;">Класификация на методите</span></h2>
<p><span style="color: #000000;">Измерванията на активността най-общо се разделят на два основни типа</span></p>
<p><span style="color: #000000;"><strong><em>Абсолютни измервания на активности</em></strong></span></p>
<p align="justify"><span style="color: #000000;">Измерванията на активността са “абсолютни” или “директни (преки)” ако дават активността на пробата според дефиницията, т.е. ако броят на ядрените превръщания в даден интервал от време са преброени директно или ако този брой може да бъде изведен пряко от измерването без използването на какъвто и да е източник с позната активност.</span></p>
<p><span style="color: #000000;">Абсолютните методи са приоритет на Националните Метрологични Институти (НМИ, NIM – National Institutes of Metrology)</span></p>
<p><span style="color: #000000; text-decoration: underline;">Примери за абсолютни измервания на активност:</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   Калориметричен метод,</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   4π- и 2π- броене,</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   Метод на съвпаденията (4pag- и 4pbg- , екстраполиране на ефективността и др.),</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   Метода на определения пространствен ъгъл,</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   TDCR метод (Triple to double coincidence ratio)</span></p>
<p align="justify"><span style="color: #000000;">За рутинните измервания на активност, абсолютните методи са рядко използвани поради тяхната сложност и сравнително голямата продължителност на измерването.</span></p>
<p><span style="color: #000000;"><strong><em>Относителни измервания на активности</em></strong></span></p>
<p align="justify"><span style="color: #000000;">Относителните измервания на активност с подходящ детектор, който е калибриран с еталонни радиоактивни източници по един или няколко радионуклида са много по-прости.</span></p>
<p><span style="color: #000000;">Точността на относителните измервания на активности зависи най-вече от  два фактора;</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-  възпроизводимостта на геометрията източник – детектор;</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;">- възможността да се изготви еталон със същите геометрични размери, плътност, химичен и радионуклиден състав като пробата, и чиято активност се различава от тази на пробата с не повече от 10¸100 пъти.</span></p>
<p><span style="color: #000000;">При тези условия неопределеността на измерването е ограничена от:</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;"> - неопределеността на еталонните източници и от</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;"> - статистиката на процеса на детектиране.</span></p>
<p align="justify"><span style="color: #000000;">В практиката обаче много често горните условия не могат да бъдат изпълнени, което налага въвеждане на корекции и в крайна сметка се увеличава неопределеността на измерването.</span></p>
<p><span style="color: #000000; text-decoration: underline;">Примери за относителни измервания на активност:</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   Метод на g–йонизационна камера от кладенчов тип,</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   Гама-спектрометрия,</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   Измерване на обща алфа- и обща бета- активност,</span></p>
<p style="padding-left: 30px;"><span style="color: #000000;">-   Течно-сцинтилационно броене.</span></p>
<p align="justify"><span style="color: #000000;">Изброените методи не са равностойни както по отношение на обхвата на измерваната стойност на активността на нуклидите така и по отношение на точността на резултатите от измерванията.</span></p>
<h5><span style="color: #000000;"><em><strong>Автор: Станислав Станев</strong></em>  </span></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/methods-measure-activity/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Основни принципи за реализиране на проследимост при измерването на активност</title>
		<link>http://metroion.com/traceability-activity/</link>
		<comments>http://metroion.com/traceability-activity/#comments</comments>
		<pubDate>Sat, 22 Sep 2012 13:36:10 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Област Активност]]></category>
		<category><![CDATA[активност]]></category>
		<category><![CDATA[активност на радионуклиди]]></category>
		<category><![CDATA[еквивалентност]]></category>
		<category><![CDATA[еталон]]></category>
		<category><![CDATA[междулабораторни сравнителни измервания]]></category>
		<category><![CDATA[международен]]></category>
		<category><![CDATA[международен и национален еталон]]></category>
		<category><![CDATA[международна еквивалентност]]></category>
		<category><![CDATA[национален]]></category>
		<category><![CDATA[проследимост]]></category>
		<category><![CDATA[първични еталони]]></category>
		<category><![CDATA[радионуклиди]]></category>
		<category><![CDATA[система за проследимост]]></category>

		<guid isPermaLink="false">http://localhost/MetroIon/?p=1038</guid>
		<description><![CDATA[Проследимост – свойство на резултат от измерване или стойност на еталон, които могат да бъдат свързани с установени еталони, обикновено международни или национални, които имат обявени неопределености с посочени доверителни вероятности чрез непрекъсната верига от сравнения. Проследимостта  установява действителността на калибрирането на определен еталон или средството за измерване, посредством последователно сравняване с по-добри еталони докато<a href="http://metroion.com/traceability-activity/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;"><strong><em>Проследимост</em></strong> – свойство на резултат от измерване или стойност на еталон, които могат да бъдат свързани с установени еталони, обикновено международни или национални, които имат обявени неопределености с посочени доверителни вероятности чрез непрекъсната верига от сравнения.</span></p>
<p align="justify"><span style="color: #000000;">Проследимостта<strong><em> </em></strong> установява действителността на калибрирането на определен еталон или средството за измерване, посредством последователно сравняване с по-добри еталони докато се стигне до точно определен първичен еталон.</span></p>
<p align="justify"><span style="color: #000000;"><strong><em>Калибриране  </em></strong>– <strong><em> </em></strong>Съвкупност от действия, които при определени условия установяват зависимостта между стойностите на величината, показани от измерителен уред, измерителна система или стойностите са представени от мярка или стандартен образец и съответните стойности, реализирани от еталоните.<span id="more-1038"></span></span></p>
<p align="justify"><span style="color: #000000;">Нивата  на проследимост, според международния речник по метрологията (VIM) са:</span></p>
<p><span style="color: #000000;">            <strong>Ниво 1</strong> – Първични еталони и международната еквивалентност.</span></p>
<p align="justify"><span style="color: #000000;">Включва реализиране на първични еталони за активност чрез развитието на методи и измерителни системи за сертифициране (стандартизиране), участие в международни сравнения, прилагането на системи за качество.</span></p>
<p><span style="color: #000000;">            <strong>Нива 2 и 3</strong> – осиуряване на проследимост на Национално ниво.</span></p>
<p align="justify"><span style="color: #000000;">Ниво 2 се състои в реализирането на вторични еталонни (референтни) системи, а ниво 3 основно осигурява националното разпространение на еталоните за активност.</span></p>
<p align="justify"><span style="color: #000000;">Международната система за проследимост на измерванията на активности включва тясно сътрудничество между много от водещите в света еталонни лаборатории за измерване на активност. Тя обхвяща две основни мероприятия организирани от BIPM:</span></p>
<p align="justify"><span style="color: #000000;">(1) чести междулабораторни сравнителни измервания на специфична активност на радиоактивни разтвори, капсулирани в стандартни стъклени ампули и всички приготвени от един и същ изходен разтвор, и     </span></p>
<p align="justify"><span style="color: #000000;">(2)  Международна Референтна Система (SIR), която позволява националните лаборатории да предават ампули съдържащи g-излъчващи радиоактивни разтвори с декларирана специфична активност на BIPM с цел проверка на резултата и регистриране (вписване) в базата данни.</span></p>
<p style="text-align: center;"><span style="color: #000000;"><a href="http://metroion.com/wp-content/uploads/2012/09/New-Picture3.png" target="_blank"><span style="color: #000000;"><img class="aligncenter  wp-image-1041" title="Compare activity" src="http://metroion.com/wp-content/uploads/2012/09/New-Picture3-300x173.png" alt="" width="397" height="231" /></span></a></span></p>
<p><span style="color: #000000;"> </span></p>
<p align="justify"><span style="color: #000000;">Реализирането на проследимостта при измерване на активности може да се представи  най-общо чрез следната схема:</span><span style="color: #000000;"> </span></p>
<p align="center"><span style="color: #000000;"><a href="http://metroion.com/wp-content/uploads/2012/09/Realisation-traceability-of-activity.bmp" target="_blank"><img class="wp-image-1052 alignnone" style="border: black 1px solid;" title="Realize traceability of activity" src="http://metroion.com/wp-content/uploads/2012/09/Realisation-traceability-of-activity.bmp" alt="" /></a></span></p>
<h5 align="center"><span style="color: #000000;">Реализиране на проследимостта при измерване на активност</span><span style="color: #000000;"> </span></h5>
<p align="justify"><span style="color: #000000;">Няма пряко отношение между понятията международен и национален еталон от една страна и първичен и вторичен еталон от друга страна. В повечето случаи международните или националните еталони са първични, но това не е задължително. Например т.нар. Международна Референтна Система за измерване на активност на g-излъчващи нуклиди (International Reference System – SIR) е вид вторичен международен еталон изграден на основата на ионизационна камера от кладенчов тип, който се съхранява в МБМТ (BIPM) и служи за допълване и разширяване на дейността на МБМТ по провеждане на международни сравнения по величината активност. Също така много от националните еталони за активност са реализирани като вторични еталони осигуряващи относителни измервания (well-type IC, LSC, GS), а заедно с това институции, нямащи статут на национални лаборатории могат да притежават първични еталони позволяващи абсолютни измервания.</span></p>
<p align="justify"> </p>
<h5><span style="color: #000000;"><em><strong>Автор: Станислав Станев</strong></em> </span> </h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/traceability-activity/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Основни понятия в радионуклидната метрология</title>
		<link>http://metroion.com/concepts-metrology-nuclide/</link>
		<comments>http://metroion.com/concepts-metrology-nuclide/#comments</comments>
		<pubDate>Sat, 22 Sep 2012 12:49:41 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Категории]]></category>
		<category><![CDATA[Област Активност]]></category>
		<category><![CDATA[активност]]></category>
		<category><![CDATA[активност на радионуклиди]]></category>
		<category><![CDATA[Еталонен (референтен) радиоактивен източник]]></category>
		<category><![CDATA[източник на йонизиращо лъчение]]></category>
		<category><![CDATA[ИЙЛ]]></category>
		<category><![CDATA[международен и национален еталон]]></category>
		<category><![CDATA[международната еквивалентност]]></category>
		<category><![CDATA[проследимост]]></category>
		<category><![CDATA[първични еталони]]></category>
		<category><![CDATA[радиоактивен източник]]></category>
		<category><![CDATA[сертифициран сравнителен материал]]></category>
		<category><![CDATA[ССМ]]></category>

		<guid isPermaLink="false">http://localhost/MetroIon/?p=994</guid>
		<description><![CDATA[Еталон – добре охарактеризиран инструмент (измерителна система) или материал, предназначен да дефинира, създава, възпроизвежда или съхранява размера на единицата на дадена физична величина, в случая, активност (или сходни величини). Основната роля на всеки един еталон за активност, е да се даде възможност резултатът от дадено измерване, да бъде представен като величина, със съответната числена стойност<a href="http://metroion.com/concepts-metrology-nuclide/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;"><strong>Еталон – </strong>добре охарактеризиран инструмент (измерителна система) или материал, предназначен да дефинира, създава, възпроизвежда или съхранява размера на единицата на дадена физична величина, в случая, <em>активност</em> (или сходни величини).</span></p>
<p align="justify"><span style="color: #000000;">Основната роля на всеки един еталон за активност, е да се даде възможност резултатът от дадено измерване, да бъде представен като величина, със съответната числена стойност и единица, за целите и нуждите на потребителите в тази област.<span id="more-994"></span></span></p>
<ul>
<li>
<div align="justify"><span style="color: #000000;"><strong>Радиоактивен Източник (РАИ) / Източник на Йонизиращо Лъчение (ИЙЛ):</strong> всеки вид материл в произволно агрегатно състояние, съдържащ един или няколко вида радиоактивни нуклиди (радионуклиди). РАИ могат да се разделят в следните групи:</span></div>
</li>
</ul>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;"><strong>- Еталонен (референтен) радиоактивен източник</strong> – РАИ, сертифициран по вличините <em>активност</em> и/или <em>скорост на излъчване на частици от повърхност </em>със съответната деклариана неопределеност<em>,</em> заедно с указания за вида на нуклида, вида и енергията на лъченията и др. важни характеристики.</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;"><strong>- Сертифициран Сравнителен Материал (ССМ)</strong> &#8211; РАИ, сертифициран както по величините <em>активност</em> и/или <em>скорост на излъчване на частици от повърхност</em>, така и по други съществени за даден експеримент параметри, напр. хомогенност, плътност и/или дебелината  активния слой, химичен състав на матрицата, съдържание на радиоактивни примеси, дебелина на подложката, или по-общо, характеристики на съда в който е поместен РАИ и др.</span></p>
<p style="padding-left: 30px;" align="justify"><span style="color: #000000;"><strong>- Радиоактивна Проба</strong> – РАИ, който подлежи на измерване (анализ) и към който могат да се предявяват определени изисквания по отношение на някои негови характеристики, в зависимост от спецификата на конкретното измерване.</span></p>
<p align="justify"><span style="color: #000000;">Всеки ССМ е еталон и в много случаи понятията еталонен РАИ и ССМ се припокриват в своя обхват.</span></p>
<p align="justify"><span style="color: #000000;">Така дефинираните еталонни РАИ и ССМ могат да служат за калибриране на инструментите, с цел те да се използват за количествена оценка на активността на същите радионуклиди (или понякога и други), в подходящи конфигурации.</span></p>
<ul>
<li>
<div align="justify"><span style="color: #000000;"><strong>Активност,</strong> <strong><em>А</em></strong> (на радиоактивен източник) &#8211; отношението  на средния брой спонтанни ядрени превръщания (разпадания) в радиоактивния източник за малък интервал от време и продължителността на този интервал.<img class="wp-image-1030 aligncenter" title="New Picture" src="http://metroion.com/wp-content/uploads/2012/09/New-Picture2.png" alt="" width="75" height="49" /></span><span style="color: #000000;">Единицата за Активност  в системата SI е бекерел (Bq):  1 Bq = 1 s<sup>-1</sup></span></div>
</li>
</ul>
<p align="justify"><span style="color: #000000;">Все още в много случаи се използва и споменатата величина кюри (Ci): 1Ci = 3,7.10<sup>10</sup> Bq</span></p>
<p align="justify"><span style="color: #000000;">За да се характеризира дадено радиоактивно вещество, в допълнение към активността трябва да се посочат радионуклида и времето към което се отнася активността (<em>референтно време</em>).</span></p>
<p align="justify"><span style="color: #000000;">Ако веществото съдържа повече от един радионуклид, всички индивидуални активности трябва да бъдат посочени.</span></p>
<p align="justify"><span style="color: #000000;">Стойността на общата активност в повечето случаи е безполезна.</span></p>
<p align="justify"><span style="color: #000000;">Въвеждат се още понятията <strong><em>специфична активност</em></strong> и <strong><em>концентрация на активността</em></strong>:</span></p>
<ul>
<li>
<div align="justify"><span style="color: #000000;"><strong>Специфична активност (масова активност), <em>а</em></strong> – активността,  разделена на масата на радиоактивния източник (проба).</span></div>
</li>
<li>
<div align="justify"><span style="color: #000000;"><strong>Концентрация на активността (обемна активност), c<sub>A</sub></strong> – активността, разделена на обема на радиоактивния източник (проба).</span></div>
</li>
<li>
<div align="justify"><span style="color: #000000;"><strong>Скорост на излъчване на частици от повърхност </strong>/surface emission rate of a source/,<strong> <em>q<sub>2π</sub></em>  &#8211; </strong>броят частици от даден вид и над определена енергия, които се излъчват от повърхността на източника за единица време. Единицата за скорост на излъчване на частици от повърхността на радиоактивния източник е частици.s-1</span></div>
</li>
</ul>
<p align="justify"><span style="color: #000000;">Поради разликите в свойствата на реалните повърхности да абсорбират и разсейват лъченията, не съществува проста връзка между активността и скоростта на излъчване на частици от повърхността.</span></p>
<p align="justify"> </p>
<h5><span style="color: #000000;"><em><strong>Автор: Станислав Станев</strong></em></span> </h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/concepts-metrology-nuclide/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Категории на измерване на Средства за измерване (СИ)</title>
		<link>http://metroion.com/categories-measuring-devices/</link>
		<comments>http://metroion.com/categories-measuring-devices/#comments</comments>
		<pubDate>Fri, 14 Sep 2012 08:35:16 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Метрология]]></category>
		<category><![CDATA[измерване]]></category>
		<category><![CDATA[изпитване на типа]]></category>
		<category><![CDATA[калибриране]]></category>
		<category><![CDATA[рутинно калибриране]]></category>
		<category><![CDATA[специално калибриране]]></category>
		<category><![CDATA[тест]]></category>
		<category><![CDATA[цели на калибрирането]]></category>

		<guid isPermaLink="false">http://localhost/MetroIon/?p=935</guid>
		<description><![CDATA[&#160; Измерване – съвкупност от действия, които имат за цел да се определи дадена стойност на величина. Калибриране – съвкупност от действия, които при определени условия установяват зависимостта между стойностите на величините, показани от измервателния уред или измервателната система, или стойностите, представени от мярка или сравнителен материали съответните стойности на величината, реализирани от еталоните. Тест<a href="http://metroion.com/categories-measuring-devices/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p>&nbsp;</p>
<p align="justify"><span style="color: #000000;"><span style="text-decoration: underline;">Измерване</span> – съвкупност от действия, които имат за цел да се определи дадена стойност на величина.</span></p>
<p align="justify"><span style="color: #000000;"><span style="text-decoration: underline;">Калибриране</span> – съвкупност от действия, които при определени условия установяват зависимостта между стойностите на величините, показани от измервателния уред или измервателната система, или стойностите, представени от мярка или сравнителен материали съответните стойности на величината, реализирани от еталоните.</span></p>
<p align="justify"><span style="color: #000000;"><span style="text-decoration: underline;">Тест</span> &#8211; тестовете са измервания, предназначени да се потвърди, че даден инструмент функционира правилно, и / или количествено определяне на вариациите на показанието на инструмента през целият му обхват, както и електрическите и условията на заобикалящата среда.<span id="more-935"></span></span></p>
<p><span style="color: #000000;"><strong>Основните цели на калибрирането</strong>:</span></p>
<p align="justify"><span style="color: #000000;">(1)  За да се гарантира, че инструмента работи правилно и следователно ще бъде подходящ за целите на предназначението му.</span></p>
<p align="justify"><span style="color: #000000;">(2)  За да се определи, при контролиран набор от стандартни условия, отчитането на стойността от инструмента като функция от стойността на измерваната величина (величината, която трябва да бъде измерена). Това трябва да стане в целият посочен обхват на инструмента.</span></p>
<p align="justify"><span style="color: #000000;">(3)  За да регулирате инструмента след калибрирането, ако е възможно, така че цялостната точност на измерване на инструмента да се оптимизира.</span></p>
<p align="justify"><span style="color: #000000;">Можем да разграничим четири различни категории на измерване на инструменти, като общопризнати, и те са:</span></p>
<p align="justify"><span style="color: #000000;"><strong>Изпитвания на типа</strong> &#8211; Тези тестове обикновено се извършват от Национални или Вторични лаборатории, които могат да предоставят информацията на разположение на потребителя на инструмента. Тестовете са предназначени за определяне на характеристиките на даден тип или модел инструмент. Те включват обширно изпитване в широк диапазон на величини, които могат да имат влияние върху резултатите от измерването, без да са обект на измерването &#8211; &#8220;влияещи величини&#8221;. </span></p>
<p align="justify"><span style="color: #000000;"><strong>Специално калибриране</strong> &#8211; В някои специални случаи на измервания, подобни на тези от изпитванията, в хода на работа са необходими специални калибрирания. Те трябва да бъдат извършени, например, ако дозиметъра или радиометъра се експлоатира при необичайни обстоятелства или ако рутинното калибриране или изпитване на типа  не предоставя достатъчна информация.</span></p>
<p align="justify"><span style="color: #000000;"><strong>Рутинно калибриране</strong> &#8211; Те са предназначени да се определи калибрационния фактор за рутинното прилагане на дозиметъра. Рутинното калибриране може да бъде с потвърдителен характер, когато е или се извършва, за да се провери, калибриране, извършено от производителя, или за да се провери дали калибрационния фактор е достатъчна устойчивост по време на продължаване на дългосрочната употреба на дадения дозиметър. </span></p>
<p align="justify"><span style="color: #000000;"><strong>Тест на приемане</strong> &#8211; Това са договорните тестове, проведени върху всички инструменти на определен тип, преди да бъдат пуснати в експлоатация за първи път. Те са предназначени да покажат, че всеки инструмент в една пратка е в съответствие с неговата спецификация.</span></p>
<p align="justify"> </p>
<h5 align="justify"><em><strong><span style="color: #000000;">Автор: Росен Иванов</span></strong></em></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/categories-measuring-devices/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Оборудване на БИМ в областта на Дозиметрията</title>
		<link>http://metroion.com/equipment-bim-dosimetry/</link>
		<comments>http://metroion.com/equipment-bim-dosimetry/#comments</comments>
		<pubDate>Fri, 14 Sep 2012 07:44:11 +0000</pubDate>
		<dc:creator>MetroIon</dc:creator>
				<category><![CDATA[Област Дозиметрия]]></category>
		<category><![CDATA[БИМ]]></category>
		<category><![CDATA[Български Институт по Метрология]]></category>
		<category><![CDATA[дозиметрия]]></category>
		<category><![CDATA[източник Сs-137]]></category>
		<category><![CDATA[източник Со-60]]></category>
		<category><![CDATA[йонизационни камери]]></category>
		<category><![CDATA[Националния еталон]]></category>
		<category><![CDATA[оборудване]]></category>
		<category><![CDATA[спомагателно оборудване]]></category>

		<guid isPermaLink="false">http://localhost/MetroIon/?p=903</guid>
		<description><![CDATA[Българския Институт по Метрология притежава Националния еталон по фотонно лъчение в областта на дозиметрията, който е вторичен еталон и е проследим към PTB, Германия. С помоща на еталона се извършват калибрирания на йонизационни камери, дозиметри и еталонни уредби.  Състав на националния еталон Дозиметър „UNIDOS” с комплект от три йонизационни камери с различни номинални обеми. Енергийния обхват на<a href="http://metroion.com/equipment-bim-dosimetry/">[...]</a>]]></description>
			<content:encoded><![CDATA[<p align="justify"><span style="color: #000000;"><a title="Българския Институт по Метрология " href="http://www.bim.government.bg/" target="_blank">Българския Институт по Метрология </a>притежава Националния еталон по фотонно лъчение в областта на дозиметрията, който е вторичен еталон и е проследим към PTB, Германия. С помоща на еталона се извършват калибрирания на йонизационни камери, дозиметри и еталонни уредби.<span id="more-903"></span><strong> </strong></span></p>
<p align="justify"><span style="color: #000000;"><strong>Състав на националния еталон</strong></span></p>
<p align="justify"><span style="color: #000000;">Дозиметър „UNIDOS” с комплект от три йонизационни камери с различни номинални обеми. Енергийния обхват на камерите е от 60 kеV до 3000 кеV.</span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"><a href="http://metroion.com/wp-content/uploads/2012/09/New-Picture-2.png" target="_blank"><span style="color: #000000;"><img class="alignleft size-medium wp-image-908" title="New Picture (2)" src="http://metroion.com/wp-content/uploads/2012/09/New-Picture-2-300x223.png" alt="" width="300" height="223" /></span></a></span></p>
<p><span style="color: #000000;"><a href="http://metroion.com/wp-content/uploads/2012/09/New-Picture.png" target="_blank"><span style="color: #000000;"><img class="alignleft  wp-image-907" title="New Picture" src="http://metroion.com/wp-content/uploads/2012/09/New-Picture.png" alt="" width="159" height="121" /></span></a></span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"><a href="http://metroion.com/wp-content/uploads/2012/09/New-Picture-1.png" target="_blank"><span style="color: #000000;"><img class="alignleft size-thumbnail wp-image-906" title="New Picture (1)" src="http://metroion.com/wp-content/uploads/2012/09/New-Picture-1-150x150.png" alt="" width="150" height="150" /></span></a> </span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span></p>
<p align="justify"><span style="color: #000000;">Еталонът може да възпроизвежда величините  екпозиция, въздушна керма и еквивалентна доза от гама-лъчение.</span></p>
<p><span style="color: #000000;"><strong>Спомагателно оборудване</strong></span></p>
<p><span style="color: #000000;"><em>Еталонна уредба ЕИУ-2 с характеристики</em>:</span></p>
<p><span style="color: #000000;"><a href="http://metroion.com/wp-content/uploads/2012/09/New-Picture-11.png" target="_blank"><span style="color: #000000;"><img class="alignleft  wp-image-920" title="New Picture (1)" src="http://metroion.com/wp-content/uploads/2012/09/New-Picture-11.png" alt="" width="298" height="233" /></span></a></span></p>
<p align="justify"><span style="color: #000000;">Градуировъчна линия с дължина 250 сm и стойност на скалното деление по надлъжната ос 1 mm с устройство за закрепване и преместване на три взаимно перпендикулярни направления на еталонните йонизационни камери.</span></p>
<p align="justify"><span style="color: #000000;">Защитно колимиращо устройство с оловен коничен колиматор, формиращ на разстояние 1000 mm от геометричния център на радиоактивния източник хомогенно лъчево поле с диаметър 150 mm.</span></p>
<p align="justify"><span style="color: #000000;">Източник на гама лъчение <sup>60</sup>Со.</span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"><em>Еталонна уредба IM8/P с характеристики</em>:</span></p>
<p><span style="color: #000000;"><a href="http://metroion.com/wp-content/uploads/2012/09/New-Picture1.png" target="_blank"><span style="color: #000000;"><img class="alignleft  wp-image-922" title="New Picture" src="http://metroion.com/wp-content/uploads/2012/09/New-Picture1.png" alt="" width="300" height="388" /></span></a></span></p>
<p align="justify"><span style="color: #000000;">Градуировъчна линия 350 cm и стойност на скалното деление по надлъжната ос 1 mm с устройство за закрепване и преместване на три взаимно перпендикулярни направления на СИ.</span></p>
<p align="justify"><span style="color: #000000;">Защитно колимиращо устройство с два волфрамови конични колиматора, формиращ на разстояние 1000 mm от геометричния център на радиоактивния източник хомогенно лъчево поле с диаметър съответно 100 mm и 200 mm;</span></p>
<p align="justify"><span style="color: #000000;">Осем източника на гама лъчение: 4 източника <sup>60</sup>Со и 4 източника <sup>137</sup>Cs;</span></p>
<p align="justify"><span style="color: #000000;">Пълно компютърно управление на еталонната уредба.</span></p>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;"> </span></p>
<h5><span style="color: #000000;"><em><strong>Автор: Росен Иванов</strong></em> </span></h5>
]]></content:encoded>
			<wfw:commentRss>http://metroion.com/equipment-bim-dosimetry/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
